Scan II, Passive Infrared Motion Sensor, Externally Visible Activation LED, Field-Selectable Fail Safe/Fail Secure, 12/24 VAC/VDC, ABS Plastic Enclosure, Black
Part#: SCESCAN II-B
Hot#: 193979
Available: 13 ( 12 PHX, 1 SEA )
Notice: The info below is not item specific.
Schlage Electronic Security
The Scan II is a compact, passive infrared detector specifically designed for “request to-exit” applications. It features adjustable relay latch time, an externally visible activation LED, and two form “C” relays. The high-impact ABS plastic enclosure in black or white comes apart in 3 pieces for easy mounting and lock-in-place scanner angle adjustment. Internal angle setting marks aide optimal coverage configuration for both wall and ceiling mounting. Mounting height is 7 to 15 feet allowing coverage area of the Scan II sensor of up to 8 by 10 ft (2.4 m by 3 m).
Features:
- Adjustable relay latch time from 0.5 to 64 seconds
- Field-selectable fail safe/fail secure
- Included pattern masking kit snaps in place to narrow scan field and help prevent unwanted activations
- Activation LED is visible at a distance and can be configured to OFF as needed
- Intended for indoor use only
- Wall or ceiling mounted with lock-in-place angle adjustment
- UL294 and ULC-S319, Class 1 listed by manufacturer
- High-impact ABS plastic enclosure and internal electronics can endure temperatures of -20° to 120°F
- Inconspicuous unit is only 1.5” x 6.25” x 1.5” in either black or white
Specifications:
- Models:
- Scan II-B: black with externally visible activation LED
- Scan II-W: white with externally visible activation LE
- Power requirements:
- 12/24 VDC: 35 mA @ 12 VDC; 38 mA @ 24 VDC when activated
- 12/24 VAC: 42 mA @ 12 VAC; 48 mA @ 24 VAC when activated
- 38 Mah required for standby operation (no internal standby battery)
- Relay: Two form "C" relay contacts rated 2.0 Amp @ 30 VDC or VAC maximum for DC resistive loads
Installation Options:
- Adjustable relay latch time from 0.5 to 64 seconds
- Relay mode can be programmed to reset when timer expires or remain activated until motion stops
- Field-selectable fail safe/fail secure
- Mounting height of 7 to 15 feet (indoors only)
- Lock-in-place pattern adjustment is +/- 14° with separate settings for wall vs. ceiling application
Specifications for Schlage Electronic Security SCESCAN II-B
Other SpecsAlternate Codes | LSESCAN11-B, LSESCANII-B, LSESCANII-B BLACK, LSESCANII-BLK, SCAN II-B, SCANIIB, SCANII-BLACK, SCESCAN2-B, SCESCAN2B, SCESCAN II - B, SCESCAN-II-B, SCESCANII-B, SCESCAN II-B BLK, SCESCANII-BLK, SCHSCAN11 BLACK, SCHSCAN-II-B |
Category | Access Control, Contacts & Sensors, Hardwired |