Available: 62 ( 5 DAL, 12 DEN, 7 KAN, 3 LA, 5 PHX, 4 SAC, 15 SEA, 8 SLC, 3 STX )
Altronix
ACMCB series distribute and switch power to access control systems and accessories. They convert a 115VAC, 60Hz input into eight (8) independently controlled 12VDC or 24VDC Class 2 Rated power-limited PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Features:
- Eight (8) independently controlled Fail-Safe and/or Fail-Secure power outputs.
- Class 2 Rated power-limited PTC Protected Outputs (auto-resettable).
- Eight (8) auxiliary power outputs (unswitched).
- Output PTCs are rated @ 2.5A.
- Filtered and electronically regulated outputs.
- Supervision: AC Fail; Battery Fail and Battery Presence.
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Alarm output relay indicates that FACP input is triggered.
- Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit.
- Built-in charger for sealed lead acid or gel type batteries.
- Instantaneous transfer to stand-by batteries.
- UL Listed in the U.S. and Canada.
- Lifetime Warranty / Made in the U.S.A.
Reference Chart:
Altronix Model Number | 115VAC 60Hz Input Current Draw | 12VDC Total Output Current | 24VDC Total Output Current | Class 2 Rated PTC Protected Outputs (auto-resettable) | Individual Output Rating | Power Supply Board Input Fuse Rating | Power Supply Board Battery Fuse Rating | Batteries Accommodated by Enclosure |
---|---|---|---|---|---|---|---|---|
AL400ULACMCB | 3.5A | 4A | 3A | 8 | 2.5A | 5A/250V | 15A/32V | Up to two (2) 12AH / 12VDC |
AL400ULACMCBJ | 3.5A | 4A | 3A | 8 | 2.5A | 5A/250V | 15A/32V | Up to two (2) 18AH / 12VDC |
AL600ULACMCB | 3.5A | 6A | 6A | 8 | 2.5A | 5A/250V | N/A | Up to two (2) 12AH / 12VDC |
AL600ULACMCBJ | 3.5A | 6A | 6A | 8 | 2.5A | 5A/250V | N/A | Up to two (2) 18AH / 12VDC |
AL1012ULACMCB | 2.6A | 10A | N/A | 8 | 2.5A | 5A/250V | 15A/32V | Up to two (2) 12AH / 12VDC |
AL1012ULACMCBJ | 2.6A | 10A | N/A | 8 | 2.5A | 5A/250V | 15A/32V | Up to two (2) 18AH / 12VDC |
AL1024ULACMCB | 4.2A | N/A | 10A | 8 | 2.5A | 6.3A/250V | 15A/32V | Up to two (2) 12AH / 12VDC |
AL1024ULACMCBJ | 4.2A | N/A | 10A | 8 | 2.5A | 6.3A/250V | 15A/32V | Up to two (2) 18AH / 12VDC |
Specifications:
- Input:
- Voltage: 115VAC, 60Hz.
- Input Fuse: Varies, see Reference Chart.
- Outputs: Class 2 Rated power-limited PTC Protected Outputs (auto-resettable).
- Voltage: 12VDC or 24VDC, see Reference Chart.
- Current: Varies, depending on the model.
- Protection: PTC 2.5A.
- Auxiliary: 3.5A (unswitched).
- Other: Overvoltage protection. Filtered and regulated outputs.
- Back-up Battery: (not included)
- Capacity:
- 12AH / 12VDC (1 or 2 within enclosure).
- 18AH / 12VDC (requires larger “J” enclosure).
- 40 AH / 65 AH (requires separate enclosure).
- Type: Sealed lead acid or gel type.
- Fuse Rating: 15A @ 32VDC. (AL600ULACMCB(J) does not have a battery fuse.)
- Failover: Upon AC loss, instantaneous.
- Fire Alarm Disconnect:
- Latching or non-latching, individually.
- selectable for any or all of the eight (8) outputs.
- Supervision:
- AC Failure: Form “C” contacts (rated 1A @ 28VDC).
- Battery: Form “C” contacts (rated 1A @ 28VDC).
- Indicators (LED):
- Input: 115VAC is present.
- DC Output: Powered.
- Battery: Discharged or not connected.
- Relays: Individual LEDs indicate outputs are triggered (relays energized).
- FACP: Indicates FACP disconnect is triggered.
- Agency Listings:
- UL: UL294 Access Control System Units.
- cUL: CSA C22.2 No.205 Signal Equipment.
- AL400ULACMCB(J), AL600ULACMCB(J) only: CSFM California State Fire Marshall Approved.
- Physical and Environmental:
- Enclosure Dimensions (H x W x D):
- AL400ULACMCB, AL600ULACMCB, AL1012ULACMCB, and AL1024ULACMCB: 15.5"(393.7mm) x 12"(304.8mm) x 4.5"(114.3mm).
- AL400ULACMCBJ, AL600ULACMCBJ, AL1012ULACMCBJ, and AL1024ULACMCBJ: 18"(457.2mm) x 14.5"(368.3mm) x 4.625"(117.48mm).
- Temperature:
- Operating: 0°C to 49°C (32°F to 120°F).
- Storage: - 20°C to 70°C (- 4°F to 158°F).
- Relative Humidity: 85% +/- 5%.
Product Weight (approx.):
Model | Product Weight |
---|---|
AL400ULACMCB | 10.7 lbs. (4.85 kg) |
AL400ULACMCBJ | 14 lbs. (6.35 kg) |
AL600ULACMCB | 10.3 lbs. (4.67 kg) |
AL600ULACMCBJ | 14.85 lbs. (6.74 kg) |
AL1012ULACMCB | 10.7 lbs. (4.85 kg) |
AL1012ULACMCBJ | 14.1 lbs. (6.40 kg) |
AL1024ULACMCB | 11.75 lbs. (5.33 kg) |
AL1024ULACMCBJ | 14.9 lbs. (6.76 kg) |
BTU/Hr. (approx.):
Model | 12VDC BTU/Hr. | 24VDC BTU/Hr. |
---|---|---|
AL400ULACMCB(J) | 25 | 37 |
AL600ULACMCB(J) | 37 | 74 |
AL1012ULACMCB(J) | 61 | N/A |
AL1024ULACMCB(J) | N/A | 123 |
Specifications for Altronix ALXAL400ULACMCB
Other SpecsAlternate Codes | AL400ULACMCB |
Category | Access Control, Alarm Power Supplies, Alarms & Intercom, Burglar Alarms, CCTV Products, Power Supplies, Wire & Power Supplies |