IML Security Supply
**** Prices updated to include tariff increases from the manufacturers. This is an ongoing process. Thank you for understanding. ****
Welcome to IML Welcome to IML
Welcome to IML Welcome to IML
Welcome to IML Welcome to IML
Welcome to IML Welcome to IML
 
8-32 Zones Control in Box 15 x 18

Part#: NAPGEM-P3200
Hot#: 115694

Please Contact your IML Representative for Details

  • Series Overview
  • Specifications
Notice: The info below is not item specific.

Napco Security Alarm


GEM-P3200 a popular, all-around 8 zone hybrid control expandable to 32 zones or 48 wireless points.

Features:

  • 8 End-of-line-resistor burglary zones programmable for area, exit/entry delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, zone ANDing and a variety of other features
  • Up to 48 points of up to 32 zones with optional zone-expansion modules 4- zone keypad EZMs (built-in)
  • Including up to 2 2-wire fire zones
  • Up to 32 individually coded users, each with a programmable authority level
  • 3 on-board relay outputs, expandable 24 external relay outputs
  • 3 keypad panics: fire, police & auxiliary
  • 2 independent area partitions
  • Up to 7 separate access stations by up to 32 users
  • Up to 24 separately-addressable X-10 devices with the GEM-X10KIT
  • English-language prompts & system status messages from choice of keypad (8) models
  • User-customized zone descriptions, reprogrammable as required
  • 2-wire and 4-wire smoke detectors
  • Reports alarms, restores and troubles by zone
  • 255 event schedule
  • 800 event log
  • Overview mode permits monitoring and control of total system from one keypad
  • 2 programmable entry delay times
  • Interior-bypass group
  • Dynamic battery test interrupts charging and places battery under load every four hours
  • Chime by zone; programmable duration
  • Non-volatile RAM retains memory during power losses
  • Quick loader programmable
  • Auto-Download log
  • Exclusive V.A.L.I.D. feature (verifying automatic line integrity diagnostic) reduces false alarms due to changes in line resistance

Specifications:

  • Operating temperature: 0-49ºC (32-120ºF)
  • Input power: 16.5Vac via class 2 plug-in 40VA transformer
  • Loop voltage: 10-13Vdc
  • Loop current: 2.5mA with 2.2ohm end-of-line resistor (model EOL2.2K); 5mA for 2-wire smoke-detector zones
  • Loop resistance: 300W max.; 50W for 2-wire smoke detector zones
  • Relay outputs (burglary; reset; aux): wet, 12Vdc, 1.2A max.; dry (cut related jumper for dry contacts), SPDT contacts 24Vdc, 2A, 0: 6 PF
  • Auxiliary power output: 12Vdc regulated
  • Remote power output: 12Vdc regulated (for keypads)
  • 650 mA combined standby current: (remote power + aux. power + reset relay power)
  • Standby time: residential fire/burglary & commercial burglary, 4 hours min.
  • EZM module: GEM-EZM8: Input, 50mA (including PGM output. PGM output: 5mA, 12V special application
  • Keypad current: GEM-RP1CAe2: 100mA; 35mA if backlighting is disabled (cut W1, W2 & W3) PGM Output: 5mA, 12V special application
  • Maximum number of keypads: 7. Maximum wiring length for each run (#22AWG): 1000’ divided by total number of keypads & EZMs on run
  • Designer keypad dimensions: 4 3/8” x 5 7/8” x 1 1/6” (HWD); 11.1cm x 14.9cm x 2.7cm (HWD)

Specifications for Napco Security Alarm NAPGEM-P3200

Other Specs
Alternate Codes115694, GEM-P3200, GEMP3200
CategoryAccess Control, Alarms & Intercom, Burglar Alarms, Control Panels/Keypads
Part TypeControl Panel