IML Security Supply
**** Prices updated to include tariff increases from the manufacturers. This is an ongoing process. Thank you for understanding. ****
Welcome to IML Welcome to IML
Welcome to IML Welcome to IML
Welcome to IML Welcome to IML
Welcome to IML Welcome to IML
 
8-96 Zones Control in Box 15 x 18

Part#: NAPGEM-P9600
Hot#: 115696

Please Contact your IML Representative for Details

  • Series Overview
  • Specifications
Notice: The info below is not item specific.

Napco Security Alarm


Gemini P9600 powerful multi-tasking hybrid control panel – feature-rich for security applications and home automation integration.

Features:

  • 8 End-of-line-resistor burglary zones programmable for area, exit/entry delay, interior, follower, day zone, chime, fire option, sensor watch, swinger shutdown, zone ANDing and a variety of other features
  • Up to 96 zones with optional zone-expansion modules and 4-zone keypads
  • Including up to 8 2-wire fire zones
  • Up to 96 individually coded users, each with a programmable authority level
  • Exclusive RS232 panel-port supports PC home automation/ networking integration for 9600 baud comprehensive communications
  • 3 On-board relay outputs; expandable to 96
  • Three keypad panics: fire, police and auxiliary
  • Up to 8 independent area partitions
  • Up to 8 separate access stations by up to 96 users
  • Up to 64 separately-addressable X-10 devices with the GEM-X10 kit
  • English-language prompts and system status messages from choice of keypad models
  • User-customized zone descriptions, reprogrammable as required
  • Supports 2-wire and 4-wire smoke detectors
  • Reports alarms, restores and troubles by zone
  • 255 Event schedule
  • 800 Event log
  • Overview mode permits monitoring and control of total system from one keypad
  • Supports up to 4 RF receivers
  • Guard-tour programmable for start time, tour length, and check points (tour stations)
  • 2 Programmable entry delay times
  • 2 Interior-bypass groups
  • Dynamic battery test interrupts charging and places battery under load every four hours
  • Chime by zone; programmable duration
  • Non-volatile RAM retains memory during power losses
  • Quick loader programmable
  • Auto-download log
  • Exclusive V.A.L.I.D. feature (verifying automatic line integrity diagnostic) reduces false alarms due to changes in line resistance

Specifications:

  • Operating temperature: 0-49ºC (32-120ºF)
  • Input power: 16.5Vac via class 2 plug-in 40VA transformer, supplied
  • Loop voltage: 10-13VAC
  • Loop current: 2.5mA with 2.2ohm end-of-line resistor (model EOL2.2K); 5mA for 2-wire smoke detector zones
  • Loop resistance: 300W max.; 50W for 2-wire smoke detector zones
  • Relay outputs (burglary; reset; aux): wet, 12Vdc, 1.2A max.; Dry (cut related jumper for dry contacts), SPDT contacts 24Vdc, 2A, 0:6 PF
  • Auxiliary power output: 12Vdc regulated
  • Remote power output: 12Vdc regulated (for keypads)
  • 750 mA combined standby current remote power + aux. power + reset relay power
  • Standby time: residential fire/burglary & commercial burglary, 4 hours minimum
  • EZM module: GEM-EZM8: input, 50mA (including PGM output) PGM output: 5mA, 12V special application
  • Keypad current: GEM-RP1CAE2: 100mA; 35mA if back lighting is disabled (cut W1, W2 & W3) PGM output: 5mA, 12V special

Specifications for Napco Security Alarm NAPGEM-P9600

Other Specs
Alternate Codes115696, GEM-P9600, GEMP9600
CategoryAccess Control, Alarms & Intercom, Burglar Alarms, Control Panels/Keypads
Part TypeControl Panel