Altronix
Maximal75D distributes and switches power to access control systems and accessories. Unit converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC and 24VDC Class 2 Rated PTC protected power-limited outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.
Features:
- Sixteen (16) independently controlled Fail-Safe and/or Fail-Secure Class 2 Rated PTC protected power-limited outputs
- Sixteen (16) auxiliary power outputs (unswitched)
- Output PTCs are rated @ 2.5A
- Filtered and electronically regulated outputs
- Supervision:
- AC Fail
- Battery Fail and Battery Presence
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Alarm output relay indicates that FACP input is triggered
- Fire Alarm disconnect input options:
- Normally open (NO) or normally closed (NC) dry contact input
- Polarity reversal input from FACP signaling circuit
- Built-in charger for sealed lead acid or gel type batteries
- Instantaneous transfer to stand-by batteries
- UL Listed in the U.S. and Canada
- Lifetime Warranty
Specifications:
- Input: 115VAC 60Hz, 7.0A input.
- Power supply input options:
- Two (2) common power input for either ACM8CB and lock power (factory installed).
- Two (2) isolated power inputs (external power supply is required), (current is determined by the power supply connected, not to exceed a maximum of 10A total).
- Sixteen (16) Access Control System trigger inputs.
- Input options:
- Sixteen (16) normally open (NO) inputs.
- Sixteen (16) open collector inputs.
- Any combination of the above.
- Output: 12VDC and 24VDC outputs.
- Maximum output current Options: 24VDC @ 9.7A plus 12VDC @ 9.5A.
- Class 2 Rated power limited outputs (auto-resettable).
- Sixteen (16) independently controlled outputs can be Fail-Safe and/or Fail-Secure power outputs.
- Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2A).
- Filtered and electronically regulated outputs (built-in power supply).
- Thermal and short circuit protection with auto reset.
- Fuse Ratings:
- Power Supply input fuse ratings:
- AL1024ULXB - 10A/250V
- AL1012ULXB - 3.5A/250V
- ACM8CB boards main fuse is rated at 10A Output fuses are rated @ 2.5A.
- Supervision:
- AC fail supervision (form "C" contacts).
- Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
- Low battery and battery presence supervision (form "C" contact).
- Battery Charging:
- Capacity: 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure).
- Type: Sealed lead acid or gel type.
- Failover: Upon AC loss, instantaneous.
- Batteries are sold separately
- Visual Indicators:
- Red LEDs indicate outputs are triggered (relays energized).
- Green LED indicates FACP disconnect is triggered.
- AC input and DC output LED indicators.
- Electrical: Temperature
- Operating: 0° C to 49° C (32° F to 120° F).
- Storage: - 20° C to 70° C ( - 4° F to 158° F).
- Relative Humidity 85% +/- 5%.
- BTU/Hr (approx.): 177 BTU/Hr.
- System AC input VA requirement: 805VA.
Specifications for Altronix ALXMAXIMAL75D