UL Motorized Latch Pullback Kit for COR ED5000/Yale 7000
Part#: CMAMLRK1-COR
Hot#: 168497
Mfg: Command Access
Available: 99+ ( 6 DAL, 14 DEN, 42 KAN, 6 LA, 15 PHX, 3 SAC, 32 SEA, 13 SLC, 28 STX )
Notice: The info below is not item specific.
Command Access Electrified Latch Retraction
The MLRK1-COR is a high quality, cost-effective method of converting a Corbin Russwin 4/5000 & Yale 7000 series device to an electrified motor-driven latch retraction exit device. All our kits retract not just the latch/latches but the push pad too. Allowing electronically dogged devices to remain in a push/pull state for as long as it is desired. Patent Pending Push to Set (PTS) Technology allows for an easy post-installation adjustment of the latch/latches. Last but not least, it Features our motor module with built-in audible diagnostics & equipped with 2 different torque settings from energy-conscious, to High Torque to get the tough jobs done.
Features:
- “PTS” Push to set technology.
- Powerfully Built & Easy to Install.
- Fast, quiet, smooth.
- True Electronic Dogging - Full push pad retraction.
- UL Listed.
- Retrofits Corbin Russwin 4/5000 & Yale 7000 series exit devices.
- MM4S Smart Module: On board diagnostics with audible feedback for adjustment and power issues.
- “PTS”: 5 second electronic adjustment for easy post installation adjustment.
- Electric dogging rated for continuous duty - Auto re-engage if push pad is pulled from dogged position.
- Low Current Draw - Field switchable to “High Torque” mode.
- Up to 300’ wire run with 2-18ga wire - Long wire runs provides installer with convenience of placing the Command locking hardware power supply in a centralized location; i.e. the same closet as the access control panel.
- 8’ cable with Quick Connect for MM4S module to easily connect to power supply lead.
- Optional Request-to-exit can be added.
- 3-year “no hassle” warranty.
Specifications:
- Voltage:
- Voltage range: 24 to 28 VDC.
- System protection: unit shutdown when voltage exceeds 28VDC.
- Standard: Average Current Peak: 900mA, Average Current Hold: 215mA.
- High Torque: Average Current Peak: 2A, Average Current Hold: 250mA.
- PTS adjustment: approx. 1/4".
- Wire Run:
- 300’: with 18ga wire.
- Product Details:
- Weight: 2 Lbs.
- Device Cutdown Details:
- 36" 4" from end cap.
- 48" 10" from end cap.
Specifications for Command Access CMAMLRK1-COR
Other SpecsAlternate Codes | CMACYLP-M-KIT, CMACYLP-UL-M-KIT, CYLP-UL-M-KIT, CYLPULMKIT, MLRK1-COR, MLRK1COR |
Category | Electrified Panic Devices, Panic Devices & Exit Alarms |