UL Motorized Latch Pullback Kit for COR ED5000/Yale 7000

Part#: CMAMLRK1-COR
Hot#: 168497

Available: 99+ ( 6 DAL, 14 DEN, 42 KAN, 6 LA, 15 PHX, 3 SAC, 32 SEA, 13 SLC, 28 STX )

  • Series Overview
  • Specifications
Notice: The info below is not item specific.

Command Access Electrified Latch Retraction


The MLRK1-COR is a high quality, cost-effective method of converting a Corbin Russwin 4/5000 & Yale 7000 series device to an electrified motor-driven latch retraction exit device. All our kits retract not just the latch/latches but the push pad too. Allowing electronically dogged devices to remain in a push/pull state for as long as it is desired. Patent Pending Push to Set (PTS) Technology allows for an easy post-installation adjustment of the latch/latches. Last but not least, it Features our motor module with built-in audible diagnostics & equipped with 2 different torque settings from energy-conscious, to High Torque to get the tough jobs done.

Features:

  • “PTS” Push to set technology.
  • Powerfully Built & Easy to Install.
  • Fast, quiet, smooth.
  • True Electronic Dogging - Full push pad retraction.
  • UL Listed.
  • Retrofits Corbin Russwin 4/5000 & Yale 7000 series exit devices.
  • MM4S Smart Module: On board diagnostics with audible feedback for adjustment and power issues.
  • “PTS”: 5 second electronic adjustment for easy post installation adjustment.
  • Electric dogging rated for continuous duty - Auto re-engage if push pad is pulled from dogged position.
  • Low Current Draw - Field switchable to “High Torque” mode.
  • Up to 300’ wire run with 2-18ga wire - Long wire runs provides installer with convenience of placing the Command locking hardware power supply in a centralized location; i.e. the same closet as the access control panel.
  • 8’ cable with Quick Connect for MM4S module to easily connect to power supply lead.
  • Optional Request-to-exit can be added.
  • 3-year “no hassle” warranty.

Specifications:

  • Voltage:
    • Voltage range: 24 to 28 VDC.
    • System protection: unit shutdown when voltage exceeds 28VDC.
    • Standard: Average Current Peak: 900mA, Average Current Hold: 215mA.
    • High Torque: Average Current Peak: 2A, Average Current Hold: 250mA.
    • PTS adjustment: approx. 1/4".
  • Wire Run:
    • 300’: with 18ga wire.
  • Product Details:
    • Weight: 2 Lbs.
  • Device Cutdown Details:
    • 36" 4" from end cap.
    • 48" 10" from end cap.

Specifications for Command Access CMAMLRK1-COR

Other Specs
Alternate CodesCMACYLP-M-KIT, CMACYLP-UL-M-KIT, CYLP-UL-M-KIT, CYLPULMKIT, MLRK1-COR, MLRK1COR
CategoryElectrified Panic Devices, Panic Devices & Exit Alarms