Access Power Controller Board Only, Output 12/24VAC/DC, (4) 2.5Amp Fused Relay Outputs, FAI Fire Alarm Interface, LED Visual Indicators

Part#: ALXACM4
Hot#: 170814
Mfg: Altronix

Available: 85 ( 8 DAL, 9 DEN, 39 KAN, 5 LA, 2 LV, 6 PHX, 4 SAC, 2 SEA, 10 STX )

Fused, not auto-resetting


  • Series Overview
  • Specifications
Notice: The info below is not item specific.

Altronix Access Power Controller


ACM4 converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Features:

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
  • FACP output relay (form “C” contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit.
  • Red LEDs indicate outputs are triggered (relays energized).
  • Green LED indicates FACP disconnect is triggered.
  • UL Listed For: Access Control System Units (UL294)
  • cUL Listed For: CSA Standard C22.2 No.205-M1983, Signal Equipment.

Specifications:

  • Input:
    • 12 to 24 volt AC or DC operation (setting not required), (0.4A @ 12volt, 0.2A @ 24 volt current consumption with all relays energized).
    • Power supply input options:
      • a) One (1) common power input (board and lock power).
      • b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power).
    • Four (4) Access Control System trigger inputs:
      • a) Four (4) normally open (NO) inputs.
      • b) Four (4) open collector sink inputs.
      • c) Any combination of the above.
  • Output:
    • Four (4) independently controlled outputs:
      • a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
      • b) Four (4) dry form “C” 5A rated relay outputs.
      • c) Any combination of the above.
    • Four (4) auxiliary power outputs (unswitched).
    • Output ratings:
      • Fuses are rated 2.5A each.
      • Main fuse is rated at 10A.
      • Note: Total output current is determined by the power supply, not to exceed a maximum of 10A. total.
  • Electrical:
    • Temperature:
      • Operating: 0° C to 49° C (32° F to 120° F).
      • Storage: - 20° C to 70° C (- 4° F to 158° F).
    • Relative Humidity: 85% +/- 5%.
    • BTU/Hr (approx.):
      • 12VDC or 12VAC: 2 BTU/Hr.
      • 24VDC or 24VAC: 3 BTU/Hr.
  • Dimensions (approximate): (WxLxH): 3.36"(85.598mm) x 5.175"(131.445) x 1.25"(31.75mm).
  • Weights (approximate): Product Weight: 0.33 Lbs. (0.149 kg).

Specifications for Altronix ALXACM4

Other Specs
Alternate CodesACM4
CategoryAccess Control, Alarm Power Supplies, Alarms & Intercom, Burglar Alarms, CCTV Products, Power Supplies, Wire & Power Supplies