KIT - 17B Storeroom Mortise Lock with Deadbolt, Inside Indicator (Locked/Unlocked) with Inside ADA Thumbturn (L583-363), Small Format IC (SFIC), Less Core, 626/US26D Satin Chrome

Part#: SCHL9480-B-17B-626 IS-LOC L583-363
Hot#: 195378

Available: 18 ( 3 KAN, 8 LA, 5 SEA, 2 SLC )

Inside Indicator LOCKED/UNLOCKED. Outside lever always fixed. Deadbolt thrown or retracted by key or thumbturn. Turning inside lever simultaneously retracts deadbolt and latchbolt.


  • Series Overview
  • Specifications
Notice: The info below is not item specific.

Schlage Lock Company L Series


The L series has long been the benchmark for grade 1 mortise locks. Beyond strength and security–it offers flexibility to meet most needs. Sixty-one mechanical functions include ten non-levered small- and large-case deadbolt functions and nine electrified functions that are regularly used as part of electronic access control systems. L Series locks have the ability to suite across electronic, tubular, exit trim, and multi-point locks to integrate seamlessly into any environment. The series features an array of security options including patented, 180-degree high visibility lock status indication trim, key override of a thumbturn being held, and support for multiple keyway families and cylinder types including Primus XP high-security cylinders.

Features:

  • Tested and certified to ANSI/BHMA grade 1 operational and security standards
  • UL listed for 3-hour fire door; spring-loaded fusible link inside lock case provides fail secure mode in case of fire
  • Deadbolt features include anti-saw pin in bolt to prevent cut-through
  • Security blocking hub prevents lock access by removing levers
  • Vandlgard option allows the outside lever to rotate freely down to prevent damage from excessive force while in a locked state
  • Lock monitoring options include request to exit (RX), latchbolt (LX), door position (DPS), and deadbolt (DM) (availability varies by function)
  • Patented Everest 29 S123 keyway is provided standard which prohibits unauthorized key duplication
  • Restricted geographically exclusive Primus upgraded security options offer advanced key control and exceptional physical security
  • Two piece anti-friction tongue in latch bolt reduces wear
  • Breakaway spindle keeps door secured in the event of vandalism
  • Field reversible latch bolt allows handing change without opening case
  • Every Schlage lock undergoes intensive testing to determine its ANSI grade level including: cycle, resistance, door impact, warped door and bolt strength tests

Specifications:

  • Chassis Case material: Cold rolled steel (CRS) with zinc dichromate plating
  • Chassis Backset: 2-3⁄4" (70 mm) only
  • Chassis Case size:
    • L9000 Series: 4-7⁄16" x 6-1⁄16" x 1" (113 mm x 154 mm x 25 mm)
    • L400 Series: 4-7⁄16" x 3-5⁄8" x 1" (113 mm x 92 mm x 25 mm)
  • Chassis Door Thickness:
    • Standard: 1-3⁄4" (44 mm)
    • Optional: 1-3⁄8" (35 mm)
    • Over 1-3⁄4" (44 mm) specify door thickness and position in door EE, EI, EO, ED
  • Spacing: Knob or lever to cylinder, 3-7/8" (98mm); knob or lever to thumbturn hub, 2-11/16" (68mm).
  • Trim Handing: L9000 Series: Field-reversible without disassembly. L400 Series: Non-handed
  • Lever/knob:
    • 33 lever designs: Forged brass and cast stainless steel
    • Two knob designs (see page 5): Heavy-duty wrought brass or stainless steel Ligature resistant lever (SL1) and knob (SK1), high security ligature resistant (HSLR) trim, HL6 hospital latch
  • Rose/Escutcheon:
    • L escutcheons: 7-15⁄16” x 1-3⁄4” x 7⁄16” (202 mm x 44 mm x 11 mm); cold-forged brass and stainless steel
    • N escutcheons: 7-7⁄8” x 2-1⁄2” x 7⁄16” (200 mm x 64 mm x 11 mm); heavy-wrought, reinforced brass and stainless steel
    • Roses: A, B, C: wrought brass and stainless steel; AVA and MER: forged brass
  • Combinations: Available with knob both sides, lever both sides, or knob/lever combinations. Roses cannot be combined with escutcheons.
  • Armor:
    • L9000 Series: Standard: 1-1⁄4" x 8" x 7⁄32" (32 mm x 203 mm x 6 mm). Optional: 1-1⁄16" x 8" x 7⁄32" (27 mm x 203 mm x 6 mm)
    • L400 Series: Standard: 1-1⁄4" x 5-9⁄16" x 7⁄32"(32 mm x 141 mm x 6 mm)
  • Latch: 3⁄4" (19 mm) throw stainless steel latch with anti-friction tongue
  • Deadbolt: 1" (25 mm) throw stainless steel deadbolt
  • Strike:
    • L9000 Series: Standard: ANSI curved lip strike 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) x 1-3⁄16" (30 mm) lip with dust box; optional: extended lip strike options (7⁄8", 1", 1-1⁄2", 1-3⁄4", 2")
    • L400 Series: Standard: 1-1⁄8" x 3-1⁄2" (29 mm x 89 mm) with dust box; optional: 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) with dust box
  • Cylinder format: 6-pin Conventional mortise cylinder (standard); also available in concealed mortise cylinder, FSIC, SFIC and 7-pin SL cylinder formats plus less cylinder options. Two nickel silver cut keys per lock.
  • Keyway: Patented Everest 29 S123 (standard); also available in open, restricted, and Primus XP security levels with available master keying and construction keying.

Standard Lever and Knob Styles:

  • 01: Width: 3.88". Projection: 2.69"
  • 02: Width: 4.75". Projection: 2.81"
  • 03 (Tubular): Width: 4.75". Projection: 2.81"
  • 05: Width: 3.75". Projection: 2.88"
  • 06 (Rhodes): Width: 4.63". Projection: 2.5"
  • 07 (Athens): Width: 4.63". Projection: 2.88"
  • 12: Width: 4.63". Projection: 3.06"
  • 17 (Sparta): Width: 4.75". Projection: 3"
  • 18: Width: 4.88". Projection: 2.69"
  • ACC (Accent): Width: 4.13". Projection: 3.13"
  • AST (Asti): Width: 4". Projection: 2.63"
  • LAT (Latitude): Width: 4.75". Projection: 2.56"
  • LON (Longitude): Width: 4.88". Projection: 2.56"
  • MER (Merano): Width: 4". Projection: 3.13"
  • OME (Omega): Width: 5.06". Projection: 3.31"
  • 41: Width: 2.21". Projection: 2.34"
  • 42: Width: 2.13". Projection: 2.54"

Non-Keyed Functions:

  • L9010: Passage latch
    • ANSI F01
    • Levers (or knobs) only-both sides; latchbolt only
    • Latchbolt retracted by lever (or knob) from either side at all times
    • Inside lever always free for immediate egress
  • L9025: Exit or communicating lock
    • ANSI F31
    • No outside trim; lever (or knob) only-inside; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from inside only
    • Inside lever always free for immediate egress
  • L/LV9040: Bath/bedroom privacy lock
    • ANSI F22
    • Emergency thumbturn access outside; thumbturn inside; latchbolt only
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by rotating inside thumbturn; Vandlgard option allows outside lever to rotate freely down while locked
    • To unlock from outside, remove access hole cover, insert emergency thumbturn (furnished) and rotate
    • Rotating inside thumbturn unlocks outside lever; turning inside lever retracts latchbolt and unlocks outside lever; closing door also unlocks preventing lock-out
    • Inside lever always free for immediate egress
    • Note: Hospital latch trim not available with Vandlgard option.
  • L/LV9040 with XL11-446: Privacy with thumbturn both sides
    • Thumbturn both sides; latchbolt only
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by rotating either thumbturn; Vandlgard option allows outside lever to rotate freely down while locked
    • Rotating either thumbturn unlocks outside lever
    • Rotating inside lever retracts latchbolt and unlocks outside lever; closing door also unlocks
    • Inside lever always free for immediate egress
    • Note: Available in rose or L escutcheon trim only.
  • L/LV9044: Privacy with coin turn outside
    • Coin turn outside; thumbturn inside; latchbolt only
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by rotating outside coin turn or inside thumbturn; Vandlgard option allows outside lever to rotate freely down while locked
    • Rotating outside coin turn unlocks outside lever
    • Rotating inside thumbturn unlocks outside lever; turning inside lever retracts latchbolt and unlocks outside lever; closing door also unlocks preventing lock-out
    • Inside lever always free for immediate egress
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L9412 with XL11-907: Exit lock with deadbolt
    • Lever (or knob) only-outside; thumbturn inside with lever; deadbolt, latchbolt and deadlocking auxiliary latch
    • Outside lever (or knob) always fixed; latchbolt retracted by inside lever
    • Deadbolt thrown or retracted by rotating inside thumbturn
    • Rotating inside lever retracts both deadbolt and latchbolt
    • Inside lever always free for immediate egress
  • L/LV9440: Privacy with deadbolt
    • ANSI F19
    • Emergency thumbturn access outside; thumbturn inside; deadbolt and latchbolt
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative when deadbolt is thrown by rotating inside thumbturn; Vandlgard option allows outside lever to rotate freely down while locked
    • To unlock from outside, remove access hole cover, insert emergency thumbturn (furnished) and rotate
    • Rotating inside thumbturn unlocks outside lever; turning inside lever retracts both deadbolt and latchbolt and unlocks outside lever
    • Inside lever always free for immediate egress
  • L/LV9444: Privacy with deadbolt and coin turn outside
    • Coin turn outside; thumbturn inside; deadbolt and latchbolt
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative when deadbolt is thrown by rotating inside thumbturn or outside coin turn; Vandlgard option allows outside lever to rotate freely down while locked
    • Rotating outside coin turn retracts deadbolt and unlocks outside lever
    • Rotating inside thumbturn unlocks outside lever; turning inside lever retracts both deadbolt and latchbolt and unlocks outside lever
    • Inside lever always free for immediate egress
    • Note: Ligature-resistant trims not available with Vandlgard option.

Single Cylinder Non-Deadbolt Functions:

  • L9026: Exit lock with cylinder
    • Key cylinder only, no lever (or knob) outside; lever only-inside; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever from inside
    • Key outside retracts latchbolt
    • Inside lever always free for immediate egress
    • Note: Available in rose or L escutcheon trim only.
  • L/LV9050: Entrance/office lock
    • ANSI F04
    • Key cylinder outside; thumbturn inside; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by key outside or by turning inside thumbturn; Vandlgard option allows both levers to rotate freely down while locked
    • Key outside unlocks outside lever and retracts latchbolt
    • Rotating inside thumbturn unlocks outside lever; turning inside lever retracts latchbolt but does not unlock
    • Inside lever always free for immediate egress
    • Caution: Egress without fully rotating the thumbturn to vertical position can result in lock-out situations.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L/LV9056, L/LV9056 with XL13-439: Entrance/office lock with automatic unlocking
    • Key cylinder outside; thumbturn inside; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by key outside or by turning inside thumbturn; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside unlocks outside lever and retracts latchbolt; XL13-439 option also allows key override of thumbturn if being held in locked position
    • Rotating inside thumbturn unlocks outside lever; turning inside lever retracts latchbolt and unlocks outside lever; closing door also unlocks preventing lock-out
    • Inside lever always free for immediate egress
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L/LV9070: Classroom lock, exterior lockdown only
    • ANSI F05
    • Key cylinder outside with lever (or knob); lever only-inside; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever from either side
    • Outside lever is made inoperative by key outside; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside unlocks outside lever and retracts latchbolt
    • Inside lever always free for immediate egress
    • Note: Outside lever remains inoperative until unlocked by key.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L/LV9076: Classroom holdback lock, exterior lockdown only
    • ANSI F06
    • Key cylinder outside with lever (or knob); lever only-inside; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever from either side
    • Outside lever is made inoperative by key outside; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside unlocks outside lever and retracts latchbolt
    • Rotate inside lever while turning key 360° to activate retracted latch holdback feature; to deactivate, reverse key rotation 360°
    • Inside lever always free for immediate egress
    • Note: Outside lever remains inoperative until unlocked by key.
    • Note: Locks with holdback feature are not UL listed. Installation should be in accordance with existing codes only.
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L/LV9080: Storeroom lock
    • ANSI F07
    • Key cylinder outside with lever (or knob); lever only-inside; latchbolt and deadlocking auxiliary latch
    • Outside lever always fixed; latchbolt retracted by inside lever; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside retracts latchbolt
    • Inside lever always free for immediate egress
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L/LV9081: Accessible storeroom lock
    • Key cylinder outside with lever (or knob); lever only-inside; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever from either side
    • Outside lever is made inoperative by key outside; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside inserted and turned 280° unlocks allowing outside lever to retract latchbolt
    • Inside lever always free for immediate egress

Double Cylinder Non-Deadbolt Functions:

  • L/LV9060: Apartment entrance lock
    • ANSI F09
    • Key cylinder both sides; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by key inside; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside retracts latchbolt but cannot lock or unlock outside lever
    • Rotating inside lever retracts latchbolt; key inside retracts latchbolt and unlocks outside lever
    • Inside lever always free for immediate egress
    • Note: Outside lever remains inoperative until unlocked by key inside.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L9066 with XL11-897: Store lock
    • Key cylinder both sides; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Both levers are made inoperative by key from either side
    • Key use on either side unlocks both levers and retracts latchbolt
    • Caution: Double cylinder locks on any door, in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only.
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L/LV9071: Classroom security lock, interior/exterior lockdown
    • ANSI F32
    • Key cylinder both sides; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by key from either side; Vandlgard option allows outside lever to rotate freely down while locked
    • Rotating inside lever retracts latchbolt; key on either side unlocks outside lever and retracts latchbolt
    • Inside lever always free for immediate egress
    • Note: Outside lever remains inoperative until unlocked by key.
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L/LV9077: Classroom security holdback lock, interior/exterior lockdown
    • Key cylinder both sides; latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative by key from either side; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside retracts latchbolt but cannot unlock outside lever
    • Rotating inside lever retracts latchbolt; key inside retracts latchbolt and unlocks outside lever
    • Rotate inside lever while turning key 360° to activate retracted latch holdback feature; to deactivate, reverse key rotation 360°
    • Inside lever always free for immediate egress
    • Note: Outside lever remains inoperative until unlocked by key inside.
    • Note: Locks with holdback feature are not UL listed. Installation should be in accordance with existing codes only.
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L/LV9082: Institution lock
    • ANSI F30
    • Key cylinder both sides; latchbolt and deadlocking auxiliary latch
    • Both levers (or knobs) always fixed; Vandlgard option allows both levers to rotate freely down while locked
    • Key on either side retracts latchbolt
    • Caution: Double cylinder locks on anydoor, in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.

Single Cylinder Deadbolt Functions:

  • L/LV9453: Entrance/office lock with deadbolt
    • ANSI F20
    • Key cylinder outside; thumbturn inside; deadbolt, latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative when deadbolt is thrown by key outside; rotating thumbturn 20° locks outside lever only; rotating thumbturn 90° also throws deadbolt; Vandlgard® option allows outside lever to rotate freely down while locked
    • Key outside retracts deadbolt and latchbolt, however, outside lever remains locked
    • Rotating inside lever retracts deadbolt and latchbolt; outside lever unlocked when thumbturn is returned to vertical position
    • Inside lever always free for immediate egress
    • Caution: Egress without fully rotating the thumbturn to vertical position can result in lock-out situations.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L/LV9456, L/LV9456 with XL13-439: Corridor lock with deadbolt
    • ANSI F13
    • Key cylinder outside; thumbturn inside; deadbolt and latchbolt
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative when deadbolt is thrown by key outside or by inside thumbturn; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside retracts deadbolt and unlocks outside lever; XL13-439 option allows key to retract deadbolt overriding thumbturn if being held in locked position
    • Rotating inside lever retracts both deadbolt and latchbolt and unlocks outside lever
    • Inside lever always free for immediate egress
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L9460 with XL11-635: Cylinder x thumbturn deadbolt with fixed levers
    • Key cylinder outside; thumbturn inside; deadbolt only
    • Both levers (or knobs) always fixed
    • Deadbolt thrown or retracted by key outside or by inside thumbturn
  • L9460 with XL11-886: Cylinder x thumbturn deadbolt with inside active lever
    • Key cylinder outside; thumbturn inside; deadbolt only
    • Outside lever (or knob) always fixed; inside lever always active
    • Deadbolt thrown or retracted by key outside or by inside thumbturn
    • Rotating inside lever retracts deadbolt
    • Inside lever always free for immediate egress
  • L9464 with XL11-886: Single cylinder deadbolt with inside active lever
    • Key cylinder outside with lever (or knob); lever only-inside; deadbolt only
    • Outside lever always fixed; inside lever always active
    • Deadbolt thrown or retracted by key outside
    • Rotating inside lever retracts deadbolt
    • Inside lever always free for immediate egress
  • L9465: Closet/storeroom lock
    • Key cylinder outside with lever (or knob); lever only-inside; deadbolt and latchbolt
    • Latchbolt retracted by lever from either side at all times
    • Deadbolt thrown or retracted by key outside
    • Caution: Deadbolt locks with outside key retraction only can result in situations where occupants can be locked in.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L9473: Dormitory/bedroom lock
    • ANSI F21
    • Key cylinder outside; thumbturn inside; deadbolt and latchbolt
    • Latchbolt retracted by lever (or knob) from either side at all times
    • Deadbolt thrown or retracted by key outside or by inside thumbturn
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L/LV9480, L/LV9480 with XL13-439: Storeroom lock with deadbolt
    • Key cylinder outside; thumbturn inside; deadbolt, latchbolt and deadlocking auxiliary latch
    • Outside lever (or knob) always fixed; latchbolt retracted by inside lever; Vandlgard option allows outside lever to rotate freely down while locked
    • Deadbolt thrown or retracted by key outside or by inside thumbturn
    • Key outside retracts deadbolt and latchbolt, however, outside lever remains locked; XL13-439 option allows key to retract deadbolt and latchbolt overriding thumbturn if being held in locked position
    • Rotating inside lever retracts both deadbolt and latchbolt
    • Inside lever always free for immediate egress
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L/LV9485, L/LV9485 with XL13-439: Faculty/hotel restroom lock with deadbolt
    • Key cylinder outside; thumbturn inside; deadbolt, latchbolt and deadlocking auxiliary latch
    • Outside lever (or knob) always fixed; latchbolt retracted by inside lever; Vandlgard option allows outside lever to rotate freely down while locked
    • Deadbolt thrown or retracted by rotating inside thumbturn
    • Key outside retracts latchbolt but does not retract deadbolt unless using an emergency key (sold separately); XL13-439 option allows emergency key to retract deadbolt and latchbolt overriding thumbturn if being held in locked position
    • Rotating inside lever retracts both deadbolt and latchbolt
    • Inside lever always free for immediate egress
    • Note: Not available in SFIC or Everest SL formats.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L9485 with XL11-557: Prison function lock
    • Key cylinder outside with knob; knob only-inside; deadbolt, latchbolt and deadlocking auxiliary latch
    • Outside knob always free spinning; latchbolt retracted by inside knob
    • Inside knob is made inoperative (fixed) when deadbolt is thrown by guard key outside
    • Guard key outside retracts deadbolt and unlocks inside knob; in unlocked state use of prisoner’s key outside retracts latchbolt only
    • Note: Available with knobs in rose or L escutcheon trim only. Tamper-resistant torx screws standard.
  • L/LV9486, L/LV9486 with XL13-439: Faculty/hotel restroom lock with chevron indicator
    • Key cylinder outside; thumbturn inside; deadbolt, latchbolt and deadlocking auxiliary latch
    • Outside lever (or knob) always fixed; latchbolt retracted by inside lever; Vandlgard® option allows outside lever to rotate freely down while locked
    • Deadbolt thrown or retracted by rotating inside thumbturn, when thrown-indicator message changes from blank to “do not disturb”
    • Key outside retracts latchbolt but does not retract deadbolt unless using an emergency key (sold separately); XL13-439 option allows emergency key to retract deadbolt and latchbolt overriding thumbturn if being held in locked position
    • Rotating inside lever retracts both deadbolt and latchbolt
    • Inside lever always free for immediate egress
    • Note: Not available in SFIC or Everest SL formats. Hospital latch trim not available with Vandlgard option.
    • To order with key override, specify function and note XL13-439 as a special option.
    • Available with A, B or C roses only; to order chevron indicator with “occupied” message specify L583-375.
  • L/LV9496, L/LV9496 with XL13-439: Corridor lock with chevron indicator
    • Key cylinder outside; thumbturn inside; deadbolt and latchbolt
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative when deadbolt is thrown by key outside or by inside thumbturn, when thrown-indicator message changes from blank to “occupied”; Vandlgard option allows outside lever to rotate freely down while locked
    • Key outside retracts deadbolt and unlocks outside lever; XL13-439 option allows key to retract deadbolt overriding thumbturn if being held in locked position
    • Rotating inside lever retracts both deadbolt and latchbolt and unlocks outside lever
    • Inside lever always free for immediate egress
    • Note: Available in rose trim only.
    • To order with key override, specify function and note XL13-439 as a special option.
    • Adds chevron style occupancy indicator (09-611) to sectional trim lock with A or B roses only.

Double Cylinder Deadbolt Functions:

  • L/LV9457: Classroom security lock with deadbolt
    • ANSI F33
    • Key cylinder both sides; deadbolt and latchbolt
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative when deadbolt is thrown by key from either side; Vandlgard option allows outside lever to rotate freely down while locked
    • Key either side retracts both latchbolt and deadbolt and unlocks outside lever
    • Rotating inside lever retracts both deadbolt and latchbolt and unlocks outside lever
    • Inside lever always free for immediate egress
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L/LV9458: Classroom security lock with deadbolt and auxiliary latch
    • ANSI F34
    • Key cylinder both sides; deadbolt, latchbolt and deadlocking auxiliary latch
    • Latchbolt retracted by lever (or knob) from either side
    • Outside lever is made inoperative when deadbolt is thrown by key from either side; Vandlgard option allows outside lever to rotate freely down while locked
    • Key either side retracts both latchbolt and deadbolt and unlocks outside lever
    • Rotating inside lever retracts both deadbolt and latchbolt and unlocks outside lever
    • Inside lever always free for immediate egress
    • Note: Ligature-resistant trims not available with Vandlgard option.
  • L9462 with XL11-886: Double cylinder deadbolt with active inside lever
    • Key cylinder both sides; deadbolt only
    • Outside lever (or knob) always fixed; inside lever always active
    • Deadbolt thrown or retracted by key from either side
    • Rotating inside lever retracts deadbolt
    • Inside lever always free for immediate egress
  • L9466: Utility room/storeroom lock
    • ANSI F14
    • Key cylinder both sides; deadbolt and latchbolt
    • Latchbolt retracted by lever (or knob) from either side
    • Deadbolt thrown or retracted by key from either side
    • Caution: Double cylinder locks on any door, in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only.
    • Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
  • L/LV9482 x XL11-543: Institution lock with deadbolt
    • Key cylinder both sides; deadbolt, latchbolt and deadlocking auxiliary latch
    • Both levers always fixed; Vandlgard option allows both leversto rotate freely down while locked
    • Deadbolt thrown or retracted by key from either side
    • Key on either side retracts both deadbolt and latchbolt
    • Caution: Double cylinder locks on any door, in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only.

Finishes:

  • 605 - Bright brass
  • 606 - Satin brass
  • 609 - Antique brass
  • 612 - Satin bronze
  • 613 - Oil rubbed bronze
  • 619 - Satin nickel
  • 622 - Matte black
  • 625 - Bright chrome
  • 626 - Satin chrome
  • 626AM - Satin chrome with antimicrobial coating
  • 629 - Bright stainless steel
  • 630 - Satin stainless steel
  • 630AM - Satin stainless steel antimicrobial
  • 643e - Aged bronze

Specifications for Schlage Lock Company SCHL9480-B-17B-626 IS-LOC L583-363

Other Specs
Alternate CodesL9480-B-17B-626 IS-LOC L583-363, L9480B-17B-626 IS-LOC L583-363, L9480B17B626ISLOCL583363, SCHL9480B-17B-626 IS-LOC L583-363
Backset2-3/4"
CategoryLock Sets, Mortise Locks, Mortise Lock Sets
Cylinder TypeLess Core, SFIC
Door ApplicationMortise Electric, Mortise Lock Body, Mortise Lock Sets
Door IndicatorsInterior Indicator - Locked/Unlocked
Finish Code626
Finish ColorBrushed Chrome, Satin Chrome
FunctionStoreroom
Lever Design17
Lock CategoryMortise Lockset - Latch and Deadbolt
Rose/EscutcheonB Rose
SeriesL Series
Thumbturn StyleLarge ADA Thumbturn