Electrified Cylindrical Lockset, 7-Pin SFIC Prep, FSE Fail Secure, Dual Voltage 12/24VDC, Clutched Galaxy Lever, SPDT, Output, ANSI Strike, Grade 1, Exterior Locked Only, Interior Free Egress, 626/US26D Satin Chrome

Part#: SDCZ7252-G5-Q
Hot#: 206429

Available: 44 ( 4 DAL, 4 DEN, 12 LA, 4 PHX, 12 SAC, 4 SEA, 4 SLC )

  • Series Overview
  • Specifications
Notice: The info below is not item specific.

Security Door Controls


Electra 7200 series solenoid controlled cylindrical locks are designed for the access control of openings in commercial, industrial and institutional facilities where code compliance, dependable operation and resistance to physical abuse are required. These code compliant electric cylindrical locksets stay latched even when unlocked, maintaining fire door integrity and eliminating the need for exposed and vulnerable electric strikes and magnetic locks or request-to-exit devices. 7200 series models incorporate a grade 1 cylindrical lockset and vandal resistant clutch – proprietary to all SDC locksets. They replace most brands of mechanical locksets making them fully compatible with new and retrofit applications.

Features:

  • Heavy duty cylindrical design
  • New or retrofit construction
  • Vandal resistant clutch
  • Solenoid control
  • Key latch retraction
  • Field selectable dual voltage
  • Power regulator included
  • Latch status (LS)
  • Optional: Request-to-exit (REX). Request-to-exit (REX) replaces latch status (LS).
  • Optional: Trim options

Models:

  • Z72: Solenoid controlled cylindrical lock

Applications:

  • Fail secure Operation: Locked when de-energized, the fail secure mode is recommended for security applications, such as inner offices, equipment rooms and security mantraps. Loss of power causes all doors to lock. Battery backup is required for continued operation during a power loss.
  • Failsafe Operation: Locked when energized, the failsafe mode is recommended for fire life safety applications, such as stairwell doors, perimeter exit doors and safety mantraps. Loss of power or a signal from the life safety system causes all doors to unlock for free uninhibited access and egress.
  • Locked Outside Only: Unlocked by an access control or key from the outside. Uninhibited egress at all times by turning the inside lever handle.

Specifications:

  • Type: Cylindrical, solenoid control
  • Door Thickness: 1-3/4” to 2”
  • Door Prep: ANSI A115.2
  • Backset: 2-3/4”
  • Latchbolt: 9/16” Throw
  • Strike: Standard ANSI 4-7/8”
  • Weight: 6 lbs
  • Input: 12/24 VDC ± 10%
  • Current Draw: 600 mA @ 12 VDC, 300 mA @ 24 VDC
  • Monitoring Contacts: SPDT 3 Amps @ 30 VDC resistive

Specify Trim:

  • E: Eclipse rose
  • G: Galaxy rose
  • E5: Eclipse rose, I-core prep
  • G5: Galaxy rose, I-core prep

Finishes:

  • Q/626 - Dull chrome
  • P/625 - Bright chrome
  • C/605 - Bright brass
  • D/606 - Dull brass
  • H/613 - Dark oil rubbed bronze

Specifications for Security Door Controls SDCZ7252-G5-Q

Other Specs
Alternate CodesZ7252-G5-Q, Z7252G5Q
CategoryCommercial Electric Locks, Cylindrical Electric Locks, Deadbolts, Electric Locks, Lock Sets, Standalone/Pushbutton Locks