Available: 9 ( 2 KAN, 7 LV )
Schlage Lock Company Electrified L Series
Many of the most advanced electronic access systems still rely on the strength and functionality of the mechanical lock hardware on the door. L Series electrified mortise locks include Schlage’s most diverse aesthetic options in a design built for performance, security and durability. It can be used as part of an integrated system or as a standalone solution with a buzzer or other device as the controller. The L Series offers exceptional flexibility and power savings. The lock automatically adapts to 12V or 24V DC input, and a case-mounted switch allows selection between EL and EU operation. Request-to-exit is modular and can be added without opening the lock case. 0.4 amp maximum current draw (24V operating voltage) allows multiple units on a single power supply, while 0.1 amp holding current eliminates “hot levers” in EL applications. Utilizing the same levers, trims and options as the mechanical Schlage L Series mortise, it suites seamlessly with the other L Series hardware which includes both purely mechanical and fully electronic solutions. And because it is based on the Schlage L mortise, it carries the same proven record of performance, strength and durability from the most trusted name in the industry.
Features:
- Universal input voltage – accepts 12V or 24V DC for installation flexibility
- User selectable fail safe/fail secure through use of switch on lock case
- Low maximum current draw allows multiple locks on a single power supply
- Low holding current produces minimal heat, eliminating “hot levers” in electrically locking applications
- Modular design allows RX feature to be added at a later time without opening the lock case
- UL listed for 3-hour fire door
- Available with Vandlgard lever engagement - ideal for areas subject to abuse or vandalism
- Extensive options for lever styles, finishes and functions
- Optional feature on two functions allows key override of the inside thumbturn when it is being held in the locked position to stop unwanted barricade situations
Available Options:
- RX: Request-to-exit
- LX: Latchbolt monitor
- DPS: Door position sensor - nondead bolt functions only
- DM: Deadbolt monitor - standard, deadbolt functions only
Specifications:
- Case material: Cold rolled steel (CRS) with zinc dichromate plating
- Case size: L9000 Series: 4-7⁄16" x 6-1⁄16" x 1" (113 mm x 154 mm x 25 mm)
- Spacing: Knob or lever to cylinder: 3-7⁄8" (98 mm); knob or lever to thumbturn hub: 2-11⁄16" (68 mm)
- Door Thickness: Standard: 1-3⁄4" (44 mm) optional: 1-3⁄8" (35 mm) to 2-1/2" (64 mm); over 2-1/2" door ranges vary by function. Specify door thickness greater than 1-3/4" and position in door EE, EI, EO, ED.
- Backset: 2-3⁄4" (70 mm) only
- Armor: Standard: 1-1⁄4" x 8" x 7⁄32" (32 mm x 203 mm x 6 mm). Optional: 1-1⁄16" x 8" x 7⁄32" (27 mm x 203 mm x 6 mm)
- Latch: 3⁄4" (19 mm) throw stainless steel latch with antifriction tongue
- Deadbolt: 1" (25 mm) throw stainless steel deadbolt
- Strike: Standard: ANSI curved lip strike 1-1⁄4" x 4-7⁄8" (32mm x 124 mm) x 1-3⁄16" (30 mm) lip with dust box; optional: extended lip strike options available
- Cylinder format: 6-pin Conventional mortise cylinder (standard); also available in concealed mortise cylinder, FSIC, SFIC and 7-pin SL cylinder formats plus less cylinder options. Two nickel silver cut keys per lock.
- Keyway: Patented Everest 29 S123 (standard); also available in open, restricted, and Primus security levels with available master keying and construction keying.
- Voltage: Auto-detects 12/24V DC operation
- Peak current: 12V operating voltage: 1 amp. 24V operating voltage: 0.4 amp
- Holding current: 0.1 amp
- Operating temperature: Maximum +120°F (+49°C). Minimum -32°F (0°C)
- Interfacing devices: Biometric devices, wall switches, security consoles, access card readers, thermosensitive devices, smoke and fire alarms, telephone access controls, automatic time devices and computerized controls
- Micro switch electrical rating for request-to-exit (RX) function and latchbolt monitor (LX): Rating: 2A @ 30V DC
Non-Keyed Functions:
- L/LV9090EL/EU: Electrically locking/unlocking outside lever, no cylinder
- Levers (or knobs) only both sides; latchbolt and deadlocking auxiliary latch
- Powered state: outside lever continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows outside lever to rotate freely down while locked
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode outside lever is locked
- Inside lever always free for immediate egress
- Note: Auto detects 12 or 24V DC.
- Note: Ligature-resistant trims not available with Vandlgard option.
- L/LV9091EL/EU: Electrically locking/unlocking both levers, no cylinder
- Levers (or knobs) only both sides; latchbolt and deadlocking auxiliary latch
- Powered state: both levers continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows both levers to rotate freely down while locked
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode both levers are locked
- Note: Auto detects 12 or 24V DC.
- Note: Ligature-resistant trims not available with Vandlgard option.
Keyed Non-Deadbolt Functions:
- L/LV9092EL/EU: Electrically locking/unlocking outside lever, outside cylinder
- Key cylinder outside with lever (or knob); lever only-inside; latchbolt and deadlocking auxiliary latch
- Powered state: outside lever continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows outside lever to rotate freely down while locked
- Key outside retracts latchbolt but cannot change the normal locked or unlocked state of outside lever
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode outside lever is locked
- Inside lever always free for immediate egress
- Note: Auto detects 12 or 24V DC.
- Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
- L/LV9093EL/EU: Electrically locking/unlocking both levers, outside cylinder
- Key cylinder outside with lever (or knob); lever only-inside; latchbolt and deadlocking auxiliary latch
- Powered state: both levers continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows both levers to rotate freely down while locked
- Key outside retracts latchbolt but cannot change the normal locked or unlocked state of either lever
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode both levers are locked
- Note: Auto detects 12 or 24V DC.
- Note: Ligature-resistant trims not available with Vandlgard option.
- L/LV9095EL/EU: Electrically locking/unlocking both levers, double cylinder
- Key cylinder both sides; latchbolt and deadlocking auxiliary latch
- Powered state: both levers (or knobs) continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows both levers to rotate freely down while locked
- Key on either side retracts latchbolt but cannot change the normal locked or unlocked state of levers
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode both levers are locked
- Note: Auto detects 12 or 24V DC.
- Note: Hospital latch and ligature-resistant trims not available with Vandlgard option.
Keyed Deadbolt Functions:
- L/LV9492EL/EU - L/LV9492EL/EU with XL13-439: Electrically locking/unlocking outside lever, outside cylinder, inside thumbturn with deadbolt
- Key cylinder outside; thumbturn inside; deadbolt, latchbolt and deadlocking auxiliary latch
- Powered state: outside lever (or knob) continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows outside lever to rotate freely down while locked
- Deadbolt thrown or retracted by key outside or by inside thumbturn; XL13-439 option allows key to retract deadbolt overriding thumbturn if being held in locked position
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode outside lever is locked; deadbolt projection is independent of electrically locked or unlocked state of outside lever
- Rotating inside lever retracts both deadbolt and latchbolt
- Inside lever always free for immediate egress
- Note: Auto detects 12 or 24V DC; supplied deadbolt monitor allows option to prevent ingress with card use when deadbolt is thrown.
- Note: Ligature-resistant trims not available with Vandlgard option
- L/LV9493EL/EU - L/LV9493EL/EU with XL13-439: Electrically locking/unlocking both levers, outside cylinder, inside thumbturn with deadbolt
- Key cylinder outside; thumbturn inside; deadbolt, latchbolt and deadlocking auxiliary latch
- Powered state: both levers (or knobs) continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows both levers to rotate freely down while locked
- Deadbolt thrown or retracted by key outside or by inside thumbturn; XL13-439 option allows key to retract deadbolt overriding thumbturn if being held in locked position
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode both levers are locked; deadbolt projection is independent of electrically locked or unlocked state of either lever
- When unlocked, rotating inside lever retracts both deadbolt and latchbolt
- Note: Auto detects 12 or 24V DC; supplied deadbolt monitor allows option to prevent ingress with card use when deadbolt is thrown.
- Note: Ligature-resistant trims not available with Vandlgard option.
- L/LV9494EL/EU: Electrically locking/ unlocking outside lever, double cylinder with deadbolt
- Key cylinder both sides; deadbolt, latchbolt and deadlocking auxiliary latch
- Powered state: outside lever (or knob) continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows outside lever to rotate freely down while locked
- Deadbolt thrown or retracted by key from either side
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode outside lever is locked; deadbolt projection is independent of electrically locked or unlocked state of outside lever
- Rotating inside lever retracts both deadbolt and latchbolt
- Inside lever always free for immediate egress
- Note: Auto detects 12 or 24V DC; supplied deadbolt monitor allows option to prevent ingress with card use when deadbolt is thrown.
- Note: Ligature-resistant trims not available with Vandlgard option.
- L/LV9495EL/EU: Electrically locking/ unlocking both levers, double cylinder with deadbolt
- Key cylinder both sides; deadbolt, latchbolt and deadlocking auxiliary latch
- Powered state: both levers (or knobs) continuously locked (EL mode) or unlocked (EU mode); Vandlgard option allows both levers to rotate freely down while locked
- Deadbolt thrown or retracted by key from either side
- When power is removed (or power fails): in EL mode either lever will retract latchbolt; in EU mode both levers are locked; deadbolt projection is independent of electrically locked or unlocked state of either lever
- When unlocked, rotating inside lever retracts both deadbolt and latchbolt
- Note: Auto detects 12 or 24V DC; supplied deadbolt monitor allows option to prevent ingress with card use when deadbolt is thrown.
- Note: Ligature-resistant trims not available with Vandlgard option.
Finishes:
- 605 - Bright brass
- 606 - Satin brass
- 609 - Antique brass
- 612 - Satin bronze
- 613 - Oil rubbed bronze
- 619 - Satin nickel
- 622 - Matte black
- 625 - Bright chrome
- 626 - Satin chrome
- 626AM - Satin chrome with antimicrobial coating
- 629 - Bright stainless steel
- 630 - Satin stainless steel
- 630AM - Satin stainless steel with antimicrobial coating
- 643e - Aged bronze (simulated equivalent)
Specifications for Schlage Lock Company SCHL9091EL-06B-626-RX
Other SpecsAlternate Codes | L9091EL-06B-626-RX, L9091EL06B626RX |
Category | Lock Sets, Mortise Locks, Mortise Lock Sets |